• warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.

Megohmmeters

Mô tả: 
Equipment used for inspection and maintenance of industrial equipment. Measure the insulation on cables, motors, generators, transformers .... 2 diagnostic levels: Measure the "Go / No go"

Megohmmeters

General characteristics

Testing and maintenance of industrial equipment

• Large measurement range from 10 kΩ to 10 TΩ

• Large backlit LCD screen, with digital display and bargraph

• Fixed test voltages and programmable test voltages from 40 V to 5,100 V

• Quantitative and qualitative insulation analysis

• Automatic calculation of the DAR / PI /DD quality ratios

• Step voltage mode

• Calculation of the result R at a reference Temperature

Main applications

• Insulation measurement on cables, motors, generators, transformers…2 levels ofdiagnostics:

–       "Go/No go" measurement

Qualitative measurement for preventive maintenance:

     -  Testing with programmed duration

              - Quality ratios: polarization index (PI) & dielectric absorption ratio (DAR)

     - Insulation testing on heterogeneous or multi-layer cables (dielectric discharge index)

-         Step voltage

• Locking of test voltages: ideal when entrusting the instrument to less experienced users

• Measurement voltage selectable from 40 to 5,100 V to deal with all types of measurement situations.

• Possibility of storing the results in the memory and exporting the data by means of software to keep a log of the measurements

SPECIFICATIONS

 

INSULATION

 

Fixed test voltages: 500 / 1,000 / 2,500 / 5,000 V

Adjustable test voltage: 40 V to 5,100 V in 10 or 100 V increments

Ranges:

500 V: 10 kΩ to 2 TΩ

1,000 V: 10 kΩ to 4 TΩ

2,500 V: 10 kΩ to 10 TΩ

5,000 V: 10 kΩ to 10 TΩ

VOLTAGE

 

 1 to 5,100 V (15 Hz to 500 Hz or DC)

CAPACITANCE

 0.001 to 49.99 F

LEAKAGE CURRENT

 0.000 nA to 3,000 A

Functions

 

Display

 Graphic

Backlighting

 YES

Programmable alarms

YES

Smoothing of display

 YES

Prog. test duration

 YES

Calculation of ratios

DAR - PI and DD

Step voltage mode

5 steps

Calc. of R at reference T°

YES

Locking of test voltage

YES

R(t)

 Directly on the display

Storage

 128 kB

RS 232

Two-way

PC software

DataView®

Power supply

 Rechargeable NiMH battery

Battery life

 

 30 days with 10 DARs and 5 PIs / day

 

Electrical safety

 IEC 61010-1 (Cat. III 1,000 V or Cat. I 2,500 V) and 61557

Dimensions

 270 x 250 x 180 mm

Weight

 4.3 kg

 