General characteristics:
- Ideal for R&D testing and design validation.
- Sources and measures DC voltage and current into your device under test.
- Combines 1 to 4 DC power supplies, DMM, oscilloscope, arbitrary waveform generator, and datalogger in 1 integrated instrument.
- Saves time – no programming required.
- Eliminates need to gather and configure multiple instruments.
- Flexible modular system: Can mix and match DC source power levels and measurement performance levels to optimize investment.
- Connect via GPIB, LAN, or USB.
- Fully compliant to LXI Class C specification.
Specifications:
DC output ratings
|
Voltage Current (derated 1% per °C above 40°C) Power |
|
50 V 5 A / 10 A 50W/ 100 W |
Output rippleand noise (PARD) (from 20 Hz – 20 MHz)
|
CV peak-to-peak CV rms |
|
4.5 mV 350 μV |
Load effect(Regulation) (for any output load change, with a maximum load-lead drop of 1 V per lead) |
Voltage Current (@ 0 - 7 V) (@ 0 - 5V) |
|
2mV 2mA 2mA |
Source effect (Regulation) |
Voltage Current |
|
1 mV 1 mA |
Programming Accuracy (at 23°C ± 5°C after 30 minute warm-up. Applies from min. to max. programming range) |
Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 100 mA, @ 0 - 7 V) (≤ 100 mA, @ 0 - 50 V) |
|
0.06% + 19 mV N/A 0.1% + 20 mA N/A N/A |
Measurement accuracy (at 23°C ± 5°C) |
Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 100 mA, @ 0 - 7 V) NOTE 1 (≤ 100 mA, @ 0 - 50 V) |
|
0.05% + 20 mV N/A 0.1% + 4 mA N/A N/A |
Programming ranges |
Voltage high range Voltage low range (≤ 5.5 V) Current high range
Current low range (≤ 0.1 A) |
|
20 mV – 51 N/A 10 mA – 5.1 A/ 10 mA – 10.2 A N/A |
Programming resolution |
Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 0.1 A) |
|
3.5 mV NOTE 2 N/A 16.3 mA NOTE N/A |
Measurement resolution |
Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 0.1 A) |
|
1.8 mV NOTE 5 N/A 410 N/A |
Programming temperature coefficient per °C |
Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 0.1 A) |
|
18 ppm + 160 μV N/A 100 ppm + 45 μA N/A |
Measurement temperature coefficient per °C |
Voltage high range Voltage low range (≤ 5.5 V) Current high range Current low range (≤ 0.1 A) |
|
25 ppm + 35 μV N/A 60 ppm + 3 μA) N/A |
Output ripple and noise (PARD) |
CC rms |
|
2 mA |
Common mode noise
|
(from 20 Hz – 20 MHz; from either output to chassis) |
|
Rms peak-to-peak |
Maximum up-programming time with full resistive load (time from 10% to 90% of total voltage excursion) |
For voltage change of up-programming time For voltage change of up-programming time |
|
0 to 10 V 0.2 ms 0 to 50 V 1.5 ms |
Maxim umup-programming settling time with full resistive load (time from start of voltage to within 50 mV of final value) |
For voltage change of up-programming settling time For voltage change of up-programming settling time |
|
0 to 10 V 0.5 ms 0 to 50 V 4.0 ms |
Maxim umdown-programming time with no load (time from start of voltage to output voltage < 0.5 V)
|
For voltage change of down-programming time For voltage change down-programming time |
|
10 to 0 V 0.3 ms 50 to 0 V 1.3 ms |
Down-programming capability
|
Continuous power Peak current |
|
7 W 7A |