• warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.

Solar Power Installation Analyser

Mô tả: 
Specially designed for solar power installations. Electrical power surveys. Solar-panel efficiency calculations. DC/AC inverter efficiency calculations

Specially designed for solar power installations!

Electrical power surveys.

Solar-panel efficiency calculations.

DC/AC inverter efficiency calculations

With the spread of solar power installations, professionals in the sector, installers, maintenance technicians and auditing organizations need a simple and effective test and measurement instrument, as the users sell on the electricity produced.

The payback time for the installation will vary according to the actual efficiency of the solar power installation. In an installation, each row of solar panels is designed to achieve a specific level of efficiency which is indicated on the datasheet concerning the panel.

When this reference value is reached, it means the installation is operating correctly. If not, it means there is a malfunction on the panel or on one of its components.

Major advantage: the FTV-100 can be used to perform these measurements simultaneously on 1, 2 or 3 rows of panels set up in parallel.

This instrument can simultaneously measure and display all the physical and electrical parameters of solar power installations. It also stores them at the same time.

 

Technical Specifications

Inputs

 

Functions

                       Range

Accuracy

Pyranometer

Solar irradiance measurement

0 to 2,000 W/m2

± 2 %

Ambient temperature

 

Pt 100 probe for measuring the ambient temperature

-30 to +80 °C

 

-30 to +80 °C

Temperature

Pt 100 probe

for measuring the temperature of the solar panels

-30 to +120 °C

± 1 % ± 1 °C

DC voltage

1 to 3 inputs

1,000 VDC

± 1 %

DC current

1 to 3 inputs

1,400 ADC

± 1 %

AC voltage

1 to 3 inputs

600 VAC

± 1 %

AC current

1 to 3 inputs

3,000 AAC

± 1 %

Functions

AC/DC power

20,000 WDC / 1,200 WAC

< 2 %

Calculation functions

 

Efficiency of solar panels with compensation

of the modules’ temperature coefficient

Efficiency of DC / AC conversion by the inverter

         

 

 

 

 