• warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.

Precision LCR Meter

Mô tả: 
All specifications apply to the conditions of a 0 to 55 °C temperature range, unless otherwise stated, and 30 minutes after the instrument has been turned on.

Measurement functions

Measurement parameters

                • Cp-D, Cp-Q, Cp-G, Cp-Rp

                • Cs-D, Cs-Q, Cs-Rs

                • Lp-D, Lp-Q, Lp-G, Lp-Rp, Lp-Rdc1

                • Ls-D, Ls-Q, Ls-Rs, Ls-Rdc1

                • R-X

                • Z-θd, Z-θr

                • G-B

                • Y-θd, Y-θr

                • Vdc-Idc1

Weight: 5.3 kg (nominal)

Outer dimensions: 375 (width) x 105 (height) × 390 (depth) mm (nominal)

Display: LCD, 320 × 240 (pixels), RGB color

The following items can be displayed:

-        Measurement value

-        Measurement conditions

-        Limit value and judgment result of comparator

-        List sweep table

-        Self-test message

Basic Specifications

Table 1. Trigger delay time

Range

0 s - 999 s

Resolution

100 μs (0 s - 100 s)

1 ms (100 s - 999 s)

Table 2. Step delay time

Range

0 s - 999 s

Resolution

100 μs (0 s - 100 s)

1 ms (100 s - 999 s)

Measurement terminal:

Four - terminal pair

Test cable length:

0 m, 1 m, 2 m, 4 m

Measurement time modes:

 Short mode, medium mode, long mode.

Table 3. Averaging

Range

1 - 256 measurements

Resolution

1

Test signal

Table 4. Test frequencies

Test frequencies

20 Hz - 2 MHz

Resolution

0.01 Hz (20 Hz - 99.99 Hz)

0.1 Hz (100 Hz - 999.9 Hz)

1 Hz (1 kHz - 9.999 kHz)

10 Hz (10 kHz - 99.99 kHz)

100 Hz (100 kHz - 999.9 kHz)

1 kHz (1 MHz - 2 MHz)

Table 5. Test signal modes

 

Normal

Program selected voltage or current at the measurement terminals when they are opened or short-circuited, respectively.

Constant

 Maintains selected voltage or current at the device under test (DUT) independently of changes in impedance of DUT.

Signal level

Table 6. Test signal voltage

Range

0 Vrms - 2.0 Vrms

Resolution

100 μVrms (0 Vrms - 0.2 Vrms)

200 μVrms (0.2 Vrms - 0.5 Vrms)

500 μVrms (0.5 Vrms - 1 Vrms)

1 mVrms (1 Vrms - 2 Vrms)

Accuracy   Normal

                  

                   Constant1

.

± (10% + 1 mVrms)  Test frequency ≤ 1 MHz: spec.

                                   Test frequency > 1 MHz: typ

± (6% + 1 mVrms)     Test frequency ≤ 1 MHz: spec.

                                   Test frequency > 1 MHz: typ.

Table 7. Test signal current

Range

0 Arms - 20 mArms

Resolution

1 μArms (0 Arms - 2 mArms)

2 μArms (2 mArms - 5 mArms)

5 μArms (5 mArms - 10 mArms)

10 μArms (10 mArms - 20 mArms)

Accuracy       Normal

                     

                       Constant1

± (10% + 10 μArms) Test frequency ≤ 1 MHz: spec.

                              Test frequency > 1 MHz: typ.   

± (6% + 10 μArms)   Test frequency < = 1 MHz: spec.

                               Test frequency > 1 MHz: typ

 

 