Published by on

Two in one: operation of each channel in differential or traditional mode
Standard delivery includes FFT and harmonics analysis
A unique level of protection: IEC 61010, Cat.III, 300 V – Cat.II, 600 V
Unequalled input dynamic: 10 mV/div. to 200 V/div. in 14 calibres
Differential inputs: 600 V max on the inputs, up to 600 V common mode
For applications up to 60 MHz
The serial oscilloscopes can be used in the laboratory or on site, even in difficult industrial environments, as shown by their installation category...
Whether the signal amplitude is high or low, this equipments offer a sufficiently wide dynamic range (from 10 mV/div. to 200 V/div.) for measurement without probes. More savings and more flexible use!
With the serials oscilloscopes, gives users the opportunity of choosing the instrument best suited to their requirements.
A complete family: 1 analogue model, 2 digital/analogue models
TECHNICAL SPECIFICATIONS |
1 |
2 |
3 |
Vertical deviation |
|
|
|
Bandwidth
|
Analogue: >30 MHz Digital: >60 MHz |
Analogue: >20 MHz Digital: >40 MHz |
Analogue: >30 MHz |
Cathode ray tube |
14 kV |
2 kV |
2 kV |
Number of channels
|
2 Differentials 2 BNCs per channel |
2 Differentials 2 BNCs per channel
|
2 Differentials 2 BNCs per channel
|
Input impedance |
1 MW / 12 pF |
1 MW / 12 pF |
1 MW / 12 pF |
Max. input voltage Điện áp đầu vào lớn nhất |
600 V Differential |
600 V Differential |
600 V Differential |
Sensitivity Độ nhạy |
10 mV – 200 V/div. |
10 mV – 200 V/div. |
10 mV – 200 V/div. |
Continuous gain adjustment |
1 to 2.5 |
1 to 2.5 |
1 to 2.5 |
Operating modes "Normal" (CH1, CH2 or CH1 & CH2.) |
CH1, CH2, ALT, CHOP, ADD, MULT, XY |
CH1, CH2, ALT, CHOP, ADD, MULT, XY |
CH1, CH2, ALT, CHOP,ADD, XY |
Operating modes "Differential" (CH1, CH2 or CH1 & CH2.) |
CH1, CH2, ALT, CHOP, ADD, MULT, XY |
CH1, CH2, ALT, CHOP, ADD, MULT, XY |
CH1, CH2, ALT, CHOP, ADD, XY |
• Horizontal deviation |
|
|
|
Time bases |
1 + Delay |
1 + Delay |
1 + Delay |
Scan speed
|
Analogue: 20 ns-200 ms/div Digital: 5 ns-200 s/div |
Analogue: 50 ns-200 ms/div Digital: 5 ns-200 s/div |
Digital: 5 ns-200 s/div |
L.V. expansion (Ana.) |
10 |
10 |
10 |
L.V. continuous adjustment (Ana.) |
1 to 2.5 |
1 to 2.5 |
1 to 2.5 |
Analogue XY mode |
2 MHz |
2 MHz |
2 MHz |
HOLD-OFF |
1 to 10 |
1 to 10 |
1 to 10 |
Z modulation |
4 MHz |
4 MHz |
4 MHz |
• Triggering |
|
|
|
Source |
CH1, CH2, ALT, LINE, EXT |
CH1, CH2, ALT, LINE, EXT |
CH1, CH2, ALT, LINE, EXT |
Coupling
|
AC, DC, LFR, HFR, TVV, TVH |
AC, DC, LFR, HFR, TVV, TVH |
AC, DC, LFR, HFR, TVV, TVH |
Sensitivity
|
Int.: 0.7 to 2 div. Ext.: 100 to 400 mV |
Int.: 0.7 to 2 div. Ext.: 100 to 400 mV |
Int.: 0.7 to 2 div. Ext.: 100 to 400 mV |
• Digital memory |
|
|
|
Max. sampling rate |
Single-shot: 100 Msam./s ETS: 20 Gsam./ |
Single-shot: 100 Msam./s ETS: 20 Gsam./ |
- |
Memory capacity |
2x (1, 8 or 16K) |
2x (1, 8 or 16K) |
- |
Vertical resolution |
8 bits |
8 bits |
- |
Converters |
2 |
2 |
- |
FFT and harmonics analysis |
Yes |
Yes |
- |
Glitch mode |
20 ns |
20 ns |
- |
Envelope mode |
Yes |
Yes |
- |
Triggered Roll Mode |
Yes |
Yes |
- |
Digital XY mode |
20 MHz |
20 MHz |
- |
• Specific features |
|
|
|
AUTOSET |
Yes |
Yes |
Yes |
Compensation of probe ratios |
1/1 , 1/10, 1/100 |
1/1 , 1/10, 1/100 |
- |
Cursors (analogue and digital) |
Vt, 1/t, phase |
Vt, 1/t, phase |
- |
Auto. measurements (ana. and digi.) |
17 |
17 |
- |
GENERAL SPECIFICATIONS |
|
|
|
Memorized configuration |
1 |
1 |
1 |
READOUT |
Yes |
Yes |
- |
Interfaces |
RS232C and Centronics |
|
RS232C and Centronics |
Interface drivers
|
PC + Printers |
|
- |
Power supply
|
110-230 V ± 10% / 50-60 Hz |
|
110-230 V ± 10% / 50-60 Hz |
Dimensions / Weight
|
435 x 330 x 163 mm / 7 kg |
|
435 x 330 x 163 mm / 6.5 kg |
IEC 61010 safety
|
Cat.III 300 V / Cat.II 600 V Class 1 |
|
Cat.III 300 V / Cat.II 600 V Class 1 |