• warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.
  • warning: preg_match() [function.preg-match]: Compilation failed: disallowed Unicode code point (>= 0xd800 && <= 0xdfff) at offset 1811 in /home/newgenco/domains/newgenco.vn/public_html/sites/all/modules/ctools/includes/cleanstring.inc on line 157.

Differential oscilloscopes

Mô tả: 
The serial oscilloscopes can be used in the laboratory or on site, even in difficult industrial environments, as shown by their installation category. A complete family: 1 analogue model, 2 digital/analogue models.


Two in one: operation of each channel in differential or traditional mode

Standard delivery includes FFT and harmonics analysis

A unique level of protection: IEC 61010, Cat.III, 300 V – Cat.II, 600 V

Unequalled input dynamic: 10 mV/div. to 200 V/div. in 14 calibres

Differential inputs: 600 V max on the inputs, up to 600 V common mode

For applications up to 60 MHz

The serial oscilloscopes can be used in the laboratory or on site, even in difficult industrial environments, as shown by their installation category...

Whether the signal amplitude is high or low, this equipments  offer a sufficiently wide dynamic range (from 10 mV/div. to 200 V/div.) for measurement without probes. More savings and more flexible use!

With the serials  oscilloscopes,  gives users the opportunity of choosing the instrument best suited to their requirements.

A complete family: 1 analogue model, 2 digital/analogue models

 

TECHNICAL SPECIFICATIONS

1

2

3

Vertical deviation

 

 

 

Bandwidth

 

Analogue: >30 MHz

Digital: >60 MHz

Analogue: >20 MHz

Digital: >40 MHz

Analogue: >30 MHz

Cathode ray tube

14 kV

2 kV

2 kV

Number of channels

 

2 Differentials

2 BNCs per channel

2 Differentials

2 BNCs per channel

 

2 Differentials

2 BNCs per channel

 

Input impedance

1 MW / 12 pF

1 MW / 12 pF

1 MW / 12 pF

Max. input voltage

Điện áp đầu vào lớn nhất

600 V Differential

600 V Differential

600 V Differential

Sensitivity

Độ nhạy

10 mV – 200 V/div.

10 mV – 200 V/div.

10 mV – 200 V/div.

Continuous gain adjustment

1 to 2.5

1 to 2.5

1 to 2.5

Operating modes "Normal"

(CH1, CH2 or CH1 & CH2.)

CH1, CH2, ALT, CHOP,

ADD, MULT, XY

CH1, CH2, ALT, CHOP,

ADD, MULT, XY

CH1, CH2, ALT, CHOP,ADD,  XY

Operating modes "Differential" (CH1, CH2 or CH1 & CH2.)

CH1, CH2, ALT, CHOP,

ADD, MULT, XY

CH1, CH2, ALT, CHOP,

ADD, MULT, XY

CH1, CH2, ALT, CHOP,

ADD,  XY

• Horizontal deviation

 

 

 

Time bases

1 + Delay

1 + Delay

1 + Delay

Scan speed

 

Analogue: 20 ns-200 ms/div

Digital: 5 ns-200 s/div

Analogue: 50 ns-200 ms/div

Digital: 5 ns-200 s/div

Digital: 5 ns-200 s/div

L.V. expansion (Ana.)

10

10

10

L.V. continuous adjustment (Ana.)

1 to 2.5

1 to 2.5

1 to 2.5

Analogue XY mode

2 MHz

2 MHz

2 MHz

HOLD-OFF

1 to 10

1 to 10

1 to 10

Z modulation

4 MHz

4 MHz

4 MHz

• Triggering

 

 

 

Source

CH1, CH2, ALT, LINE, EXT

CH1, CH2, ALT, LINE, EXT

CH1, CH2, ALT, LINE, EXT

Coupling

 

AC, DC, LFR, HFR, TVV, TVH

AC, DC, LFR, HFR, TVV, TVH

AC, DC, LFR, HFR, TVV, TVH

Sensitivity

 

Int.: 0.7 to 2 div.

Ext.: 100 to 400 mV

Int.: 0.7 to 2 div.

Ext.: 100 to 400 mV

Int.: 0.7 to 2 div.

Ext.: 100 to 400 mV

• Digital memory

 

 

 

Max. sampling rate

Single-shot: 100 Msam./s

ETS: 20 Gsam./

Single-shot: 100 Msam./s

ETS: 20 Gsam./

-

Memory capacity

2x (1, 8 or 16K)

2x (1, 8 or 16K)

-

Vertical resolution

8 bits

8 bits

-

Converters

2

2

-

FFT and harmonics analysis

Yes

Yes

-

Glitch mode

20 ns

20 ns

-

Envelope mode

Yes

Yes

-

Triggered Roll Mode

Yes

Yes

-

Digital XY mode

20 MHz

20 MHz

-

• Specific features

 

 

 

AUTOSET

Yes

Yes

Yes

Compensation of probe ratios

1/1 , 1/10, 1/100

1/1 , 1/10, 1/100

-

Cursors (analogue and digital)

Vt, 1/t, phase

Vt, 1/t, phase

-

Auto. measurements (ana. and digi.)

17

17

-

GENERAL SPECIFICATIONS

 

 

 

Memorized configuration


1

1

1

READOUT

Yes

Yes

-

Interfaces

RS232C and Centronics

 

RS232C and Centronics

Interface drivers

 

PC + Printers

 

-

Power supply

 

110-230 V ± 10% / 50-60 Hz

 

110-230 V ± 10% / 50-60 Hz

Dimensions / Weight

 

435 x 330 x 163 mm / 7 kg

 

435 x 330 x 163 mm / 6.5 kg

IEC 61010 safety

 

Cat.III 300 V / Cat.II 600 V Class 1

 

Cat.III 300 V / Cat.II 600 V Class 1

 